CDLTC - 862 3217 DOT WORKS MAJESTIC 550 RAPID ACCESS DEVELOPER
- MSDS: CDLTC
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: 862 3217 DOT WORKS MAJESTIC 550 RAPID ACCESS DEVELOPER
- National Stock Number: 6750-00D006184
Product Identification
Product ID:862 3217 DOT WORKS MAJESTIC 550 RAPID ACCESS DEVELOPER
MSDS Date:01/26/1994
FSC:6750
NIIN:00D006184
MSDS Number: CDLTC
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 716-477-3194
Cage: 19139
Contractor
Telephone: 800-828-6203
Cage: 5K871
Ingredients
HYDROQUINONE (SARA 302/313) (CERCLA)
CAS: 123-31-9
RTECS: MX3500000
Fraction By Weight: <3%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
POTASSIUM CARBONATE
CAS: 584-08-7
RTECS: TS7750000
Fraction By Weight: 1-5%
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 85-90%
POTASSIUM SULFITE
CAS: 10117-38-1
RTECS: WT3530000
Fraction By Weight: 5-10%
SODIUM SULFITE
CAS: 7757-83-7
RTECS: WE2150000
Fraction By Weight: 1-5%
Hazards
LD50 LC50 Mixture:TLVL HYDROQUINONE: 2 MG/M3
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-EXPECTED TO BE A LOW HAZARD
FOR RECOMMENDED HANDLING. EYE-CAUSES IRRITATION. SKIN-CAUSES
IRRITATION. INGESTION-HARMFUL IF SWALLOWED. MAY CAUSE BURNS OF THE
GASTROINTESTINAL TRACT.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO KNOWN
CARCINOGENS OR SUSPECT CARCINOGEN.
Effects of Overexposure:SKIN-MAY CAUSE ALLERGIC SKIN REACTION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALE-MOVE TO FRESH AIR. TREAT SYMPTOMATICALLY. GET MEDICAL
ATTENTION IF SYMPTOMS OCCUR. EYE-IMMEDIATELY FLUSH WITH WATER FOR
15 MIN. GET MEDICAL ATTENTION. SKIN-IMMEDIATELY REMOVE CONTAMINATED
CLOTH ING/SHOES & WASH WITH SOAP & WATER. GETMEDICAL ATTENTION FOR
SKIN REACTIONS. INGESTION-INDUCE VOMITING AS DIRECTED BY MEDICAL
PERSONNEL. CALL A PHYSICIAN OR POISON CONTROL CENTER IMMEDIATELY.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT MATERIAL,
THEN PLACE IN CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE
THOROUGHLY TO REMOVE RESIDUAL CO NTAMINATION.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED. KEEP AWAY FROM
INCOMPATIBLE SUBSTANCES.
Other Precautions:AVOID CONTACT WITH EYES, SKIN & CLOTHING. USE WITH
ADEQUATE VENTILATION. WASH THOROUGHLY AFTER HANDLING. THE ROUTINE
USE OF A NONALKALINE TYPE OF HAND CLEANER & REGULAR CLEANING OF
WORKING SURFACES, G LOVES, ETC. IS ADVISED.
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES PER
HOUR) SHOULD BE USED. VENTILATION RATES SHOULD MATCH CONDITIONS.
Protective Gloves:WEAR IMPERVIOUS GLOVES
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELD
Other Protective Equipment:EYE BATH, SAFETY SHOWER, WASHING FACILITIES.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING, DRINKING OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
NOT REGULATED.
Chemical Properties
HCC:B3
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:24 MBAR
Vapor Density:0.6
Spec Gravity:1.094
pH:10.5
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID. LIGHT YELLOW. ODORLESS.
Percent Volatiles by Volume:85-90
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SULFUR DIOXIDE.
Disposal
Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE AMOUNTS
OF WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.